For use in the Denver Water Service Area |
Standard Drawings
Denver Water
Effective 12/01/2004
You can download complete Engineering Standards, Materials Specifications, or the Standard Drawings in PDF format. Each document is between 1-3 Megs.
If you wish to obtain an Engineering Standard book with CAD details, they are available at Denver Water, 1600 W. 12th Ave., 3rd Floor Engineering, Denver, CO 80204, from Terri Steele at 303-628-6604. The cost is $100.00.
Attention CAD application users: All Cad files are in AutoCAD 2002 format.
If a CAD drawing does not open after clicking the link, you can save the drawing locally by right clicking the link and selecting 'Save target as'. All of the CAD drawings on this site use the color/pen width chart here – Attachment A – to conform to Denver Water’s standards for plotting. Please change the pen width values in AutoCAD accordingly, when plotting out any of the Engineering Standards drawings.
Note: These drawings are provided for standardization purposes only. They represent minimum design standards which may require upgrading for specific applications.
Formats |
||||||||||||||||||||||||||||||||
Standard Drawings |
CAD |
|||||||||||||||||||||||||||||||
Water Distribution System Typical Plan |
No. 1 | No. 1 | ||||||||||||||||||||||||||||||
Typical Street Cross Section & Street Centerline Profile |
No. 2 | No. 2 | ||||||||||||||||||||||||||||||
Typical Street Cross Section Public Street |
No. 3 | No. 3 | ||||||||||||||||||||||||||||||
Typical Street Cross Section Private Street |
No. 4 | No. 4 | ||||||||||||||||||||||||||||||
Water Distribution System Typical Plan for Curved Streets |
No. 5 | No. 5 | ||||||||||||||||||||||||||||||
Water Distribution System Typical Plan for Cul-de-Sacs |
No. 6 | No. 6 | ||||||||||||||||||||||||||||||
Plan, Profile & Locations for Fire Hydrants, Mains, & Valves |
No. 7 | No. 7 | ||||||||||||||||||||||||||||||
Piping at Street Intersections – Future Connections |
No. 8 | No. 8 | ||||||||||||||||||||||||||||||
Typical Quarter Section Hydraulic Grid System |
No. 9 | No. 9 | ||||||||||||||||||||||||||||||
Typical Trench Section – Pipe Protection |
No.10 | No.10 | ||||||||||||||||||||||||||||||
Typical Trench Section for Pipelines in Dipping Bedrock |
No.11 | No.11 | ||||||||||||||||||||||||||||||
Blowoff Installation for 12" & Smaller Pipe |
No.12 | No.12 | ||||||||||||||||||||||||||||||
Transmission Main Blowoff Installation |
No.13 | No.13 | ||||||||||||||||||||||||||||||
Detail Permanent 2" Blowoff in 48" Manhole |
No.14 | No.14 | ||||||||||||||||||||||||||||||
Valve Box Support Plate & Valve Operator Extension Guide |
No.15 | No.15 | ||||||||||||||||||||||||||||||
2" Air Valve Assembly |
No.16 | No.16 | ||||||||||||||||||||||||||||||
Air Valve Assembly with Access Manhole |
No.17 | No.17 | ||||||||||||||||||||||||||||||
Conduit Or Transmission Main, Mechanical |
No.18 | No.18 | ||||||||||||||||||||||||||||||
Concrete Kickblocks – Bearing Surfaces & Installation |
No.19 | No.19 | ||||||||||||||||||||||||||||||
Concrete Kickblock |
No.20 | No.20 | ||||||||||||||||||||||||||||||
Length Of Restrained Pipe |
No.21 | No.21 | ||||||||||||||||||||||||||||||
Tie Rod & Washer Details |
No.22 | No.22 | ||||||||||||||||||||||||||||||
Tie Rod Coupling |
No.23 | No.23 | ||||||||||||||||||||||||||||||
Flange Lug Detail |
No.24 | No.24 | ||||||||||||||||||||||||||||||
Clamp Details & Dimensions for Use with CI & DI Fittings Only |
No.25 | No.25 | ||||||||||||||||||||||||||||||
Combination Flanged Harness Lug Details |
No.26 | No.26 | ||||||||||||||||||||||||||||||
Mechanical Joint Restraint Details |
No.27 | No.27 | ||||||||||||||||||||||||||||||
Joint Restraint Detail |
No.28 | No.28 | ||||||||||||||||||||||||||||||
Bored Crossings Beneath Conduits |
No.29 | No.29 | ||||||||||||||||||||||||||||||
Bore Casing Details |
No.30 | No.30 | ||||||||||||||||||||||||||||||
Open Cut Crossing Beneath Conduit or ConflictingUtility |
No.31 | No.31 | ||||||||||||||||||||||||||||||
Crossing Storm & Sanitary Sewers |
No.32 | No.32 | ||||||||||||||||||||||||||||||
Reference Post Typical Detail |
No.33 | No.33 | ||||||||||||||||||||||||||||||
Typical Cutoff Wall for Ditch Or Canal Crossing |
No.34 | No.34 | ||||||||||||||||||||||||||||||
2" & Larger Domestic & Fireline Connections |
No.35 | No.35 | ||||||||||||||||||||||||||||||
Fireline Connections with Domestic Service Tee |
No.36 | No.36 | ||||||||||||||||||||||||||||||
Insulated Joints, Rods, & Bolted Sleeve Type Couplings |
No.37 | No.37 | ||||||||||||||||||||||||||||||
Polyethylene Wrap |
No.38 | No.38 | ||||||||||||||||||||||||||||||
Adjustable Steel Pipe Valve Support |
No.39 | No.39 | ||||||||||||||||||||||||||||||
Industrial Vent Assembly – Installation & Details |
No.40 | No.40 | ||||||||||||||||||||||||||||||
Industrial Vent Assembly – Vent Screen |
No.41 | No.41 | ||||||||||||||||||||||||||||||
Residential Vent Assembly |
No.42 | No.42 | ||||||||||||||||||||||||||||||
Pressure Regulating Valve – Manhole Installation Typical Plan |
No.43 | No.43 | ||||||||||||||||||||||||||||||
Pressure Regulating Valve – Manhole Installation Cross Section |
No.44 | No.44 | ||||||||||||||||||||||||||||||
Pressure Regulating Valve – Rectangular Vault Typical Plan |
No.45 | No.45 | ||||||||||||||||||||||||||||||
Pressure Regulating Valve – Rectangular Cross Section |
No.46 | No.46 | ||||||||||||||||||||||||||||||
General Meter Notes |
No.47 | No.47 | ||||||||||||||||||||||||||||||
Service Line, Stop Box & Outside Meter Installation |
No.48 | No.48 | ||||||||||||||||||||||||||||||
Outside Setting for 5/8-Inch x 3/4-Inch, 3/4-Inch & 1-Inch Meters |
No.49 | No.49 | ||||||||||||||||||||||||||||||
Service Line, Stop Box & Inside Meter
|
No.50 | No.50 | ||||||||||||||||||||||||||||||
Typical Inside Setting for 3/4" and 1" Meter with AMR |
No.51 | No.51 | ||||||||||||||||||||||||||||||
Typical Inside Setting for 3/4" and 1" Meter with AMR |
No.52 | No.52 | ||||||||||||||||||||||||||||||
Inside Meter Setting and Remote ERT Installation for Home Built on Slab |
No.53 | No.53 | ||||||||||||||||||||||||||||||
Meter Pit with Remote ERT Installation on Outside Building Wall |
No.54 | No.54 | ||||||||||||||||||||||||||||||
Outside Setting for 1-1/2" & 2" Meter with |
No.55 | No.55 | ||||||||||||||||||||||||||||||
Inside Setting for 1-1/2" & 2" Meter with Check Valve & Bypass |
No.56 | No.56 | ||||||||||||||||||||||||||||||
Wall Plates & Body Clamps for 3" Meters |
No.57 | No.57 | ||||||||||||||||||||||||||||||
Wall Plates for 4", 6", 8", and 10" Meters |
No.58 | No.58 | ||||||||||||||||||||||||||||||
Inside Setting for 3" & Larger Compound Meter |
No.59 | No.59 | ||||||||||||||||||||||||||||||
Compound Meter with Both Check Valve & Bypass |
No.60 | No.60 | ||||||||||||||||||||||||||||||
Compound Meter Dimensions |
No.61 | No.61 | ||||||||||||||||||||||||||||||
Compact Fireline Meter with Bypass |
No.62 | No.62 | ||||||||||||||||||||||||||||||
Compact Fireline Meter Dimensions |
No.63 | No.63 | ||||||||||||||||||||||||||||||
Instrumentation & Control Ladder Diagram Typical |
No.64 | No.64 | ||||||||||||||||||||||||||||||
Instrumentation & Control Wiring Diagram Typical |
No.65 | No.65 | ||||||||||||||||||||||||||||||
Instrumentation & Control Cabinet Layout Typical |
No.66 | No.66 | ||||||||||||||||||||||||||||||
Instrumentation & Control Detail & Schedules Typical |
No.67 | No.67 | ||||||||||||||||||||||||||||||
Instrumentation & Control P & ID – Typical |
No.68 | No.68 | ||||||||||||||||||||||||||||||
Instrumentation & Control Site Diagram – Typical |
No.69 | No.69 | ||||||||||||||||||||||||||||||
Stub-out Configuration for Future Main Extensions |
No.70 | No.70 | ||||||||||||||||||||||||||||||
Stub-out Configuration for Future Main Extensions |
No.71 | No.71 | ||||||||||||||||||||||||||||||
Valve Operations |
No.72 | No.72 | ||||||||||||||||||||||||||||||
Outside Settings for 1 1/2" & 2" Irrigation Meter in Vault |
No.73 | No.73 | ||||||||||||||||||||||||||||||
Turbine Meter |
No.74 | No.74 | ||||||||||||||||||||||||||||||
Turbine Meter Dimensions |
No.75 | No.75 | ||||||||||||||||||||||||||||||
Master Meter for Emergency Interconnection Plans & Details |
No.76 | No.76 | ||||||||||||||||||||||||||||||
Master Meter for Emergency Interconnection Details & Dimensions |
No.77 | No.77 | ||||||||||||||||||||||||||||||
Above Ground Dual System Interconnection |
No.78 | No.78 | ||||||||||||||||||||||||||||||
Below Ground Dual System Interconnection |
No.79 | No.79 | ||||||||||||||||||||||||||||||
Single Feed System Interconnection |
No.80 | No.80 | ||||||||||||||||||||||||||||||
Standard Design for Hydrant Interconnection |
No.81 | No.81 | ||||||||||||||||||||||||||||||
Pitot Installation |
No.82 | No.82 | ||||||||||||||||||||||||||||||
Standard Design for Hydrant Meter Installation |
No.83 | No.83 | ||||||||||||||||||||||||||||||
Standard Design for Blowoff Hydrant |
No.84 | No.84 | ||||||||||||||||||||||||||||||
Tracer Wire Installation for PVC Water Main |
No.85 | No.85 | ||||||||||||||||||||||||||||||
Traffic Impediment Bollard |
No.86 | No.86 | ||||||||||||||||||||||||||||||
Submerged BFV with Torque Tube and Actuator Stand |
No.87 | No.87 | ||||||||||||||||||||||||||||||
Recycled Water System Pentagon Operating Nut |
No.88 | No.88 | ||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||
Attachment A: Color/Pen Width Chart |
Attachment A | |||||||||||||||||||||||||||||||
Abbreviation List |
Abbreviations | |||||||||||||||||||||||||||||||